vi-VNen-US
EMERSON GXT3-1500RT230 1500VA / 1350W
EMERSON GXT3-1500RT230 1500VA / 1350W
GXT3-1500RT230
14.551.000 VND

  Emerson Liebert GXT3 On-Line 1500VA/1350W 230V PF0.9 2U, GXT3-1500RT230

Higher Availability

Advance Early Warning of UPS System Status

Multiple audible and visual alarms immediately alert you to an output overload, low battery, bypass, battery discharge, battery loss or replace battery condition

4-6 minutes of Battery Backup Time at Full Load at 0.9 Power Factor

Provide ample time for an orderly shutdown of connected equipment when utility power fails. Optional matching external battery cabinets offer additional backup time

Overload Capability

Designed to handle output overload conditions

Full Sequenced Battery Testing

Provides automatic and manual-self diagnostic battery testing capabilities. It analyzes the condition of the batteries within the UPS and will notify you when the internal batteries need to be replaced.

Flexibility

Up To Battery-Backed Outlets

A generous quantity of battery-backed outlets allows more equipment to be protected by the UPS

Rotatable Display Panel

The LED display panel rotates 90o to makes the readout of the LED display easy to see in rack or tower position

Automatic Frequency Sensinga

The UPS automatically adjust to the input frequency, 50 or 60 Hz

Mounting Flexibility

Optional telescoping rack rails mount to the sides of the UPS for easy installation into a rack enclosure. The UPS is provided with a standard tower support base

User Replaceable Hot Swappable Batteries

Easy to replace batteries conveniently located behind the front bezel of the unit

Power-Factor Correction

Prevents noise, harmonics and distortion from being passed on to connected loads or from being fed back to the utility

Internal Automatic and Manual Bypass Capabilty

Assures continuity of power to critical load during system problems or maintenance

Intelligent Battery Managemen

Includes efficient three-stage charging technique and comprehensive discharging protection that extends battery life for greater availability

Input Circuit Breaker

Provides increased protection to ease recovery from overloads

Lightning and Surge Protection

The transient voltage surge suppression (TVSS) circuitry inside Liebert GXT3 provides additional protection for the connected equipment from incoming spikes, surges and other power anomalies present on the incoming utility power source

Lowest Total Cost Of Ownership

0,9 Output Power Factor

Liebert GXT3 rated output power of 0,9 better matches up with switch-mode power supplies used in today IT equipment. A higher output power factor allows for a more efficient utilization of the UPS

Wide Input Voltage Window

Prolongs battery life by allowing the UPS to maximize the use of utility power before transferring to battery when input voltage exceeds specified limits

Intelligent Fan Operation

Automatically changes rotation speed depending on system requirements to decrease power consumption and noise

Efficient Operation

90% AC-AC efficiency

Warranty Protection

The industry best warranty - No -hassle  two-year warranty with UPS replacement in the event of problems. Shipping is free for both original UPS return and the replacement unit. Optional one-year and three-year extensions also available

Product Model

Parameters

GXT3-1500RT230

GXT3-2000RT230

GXT3-3000RT230

Model Rating

1500VA/1350W

2000VA/1800W

3000VA/2700W

Dimensions, D x W x H, mm (in)

Unit

497 × 430 × 85

(19.6 x 16.9 x 3.3)

602 × 430 × 85

(23.7 x 16.9 x 3.3)

Shipping

617 x 570 x 262

(24.3 x 22.4 x 10.3)

717 x 570 x 262

(28.2 x 22.4 x 10.3)

Weight, kg (lb)

Unit

23.2 (51.1)

25.5 (56.1)

32.4 (71.4)

Shipping

26 (57.3)

28 (61.7)

35 (77.2)

Input AC

Voltage Range (typical)

230VAC nominal; variable based on output load

90% ~ 100% loading

177VAC/280VAC

196VAC/280VAC

70% ~ 90% loading

168VAC/280VAC

184VAC/280VAC

30% ~ 70% loading

150VAC/280VAC

161VAC/280VAC

0 ~ 30% loading

115VAC/280VAC

115VAC/280VAC

Frequency

40Hz ~ 70Hz; Auto Sensing

Input Power Receptacle

C14

C20

Output AC

AC-AC Efficiency

> 88% AC-AC, minimum

Output Receptacles

C13 x 6

C13 x 6; C19 x 1

Voltage

220/230/240VAC (user configurable); ±3%

Frequency

50Hz or 60Hz

Waveform

Sine wave

Mains (AC) Mode Overload

200% for 2 seconds; 150% for 50 seconds

200% for 2 seconds;

150% for 55 seconds

Internal Battery Charger

Charger Current

1.88

2.71

2.5

Battery

Type

Valve-regulated, nonspillable, lead acid

Qty × V× Rating

4 × 12V × 7.2Ah

4 × 12V × 9.0Ah

6 × 12V × 9.0Ah

Battery Mfr/Part#

Panasonic/UP-RW1236 CSB/ GP 1272

Panasonic/UP-RW1245 CSB/ HR 1234W F2

Backup Time

See Table 15 - Battery run time

Recharge Time

3 hours to 90% capacity after full discharge with 100% load till UPS auto-shutdown (Internal Batteries Only)

Environmental Requirements

Operating Temp

0ºC to 40ºC (32ºF to 104ºF); Table 14 - Operating temperature parameters

Storage Temp

-15ºC to +50ºC (5ºF to 122ºF)

Relative Humidity

0%RH to 95%RH, non-condensing

Operating Elevation

Up to 3000m (10,000 ft.) at 25ºC (77ºF) without derating

Storage Elevation

15000m (50,000 ft.) maximum

Audible Noise

< 45 dBA max. at 1 meter (3.2ft.) front and side

< 46 dBA, at 1 meter (3.2ft.) rear

< 48 dBA max. at 1 meter (3.2ft.) front and side

< 48 dBA, at 1 meter (3.2ft.) rear

Agency

Safety

IEC/EN/AS 62040-1:2008, GS mark

RFI/EMI

IEC/EN/AS 62040-2 2nd Ed. (Category C2) = CISPR22 Class A

Surge Immunity

IEC/EN 62040-2 2nd Ed. (IEC/EN 61000-4-5)

Transportation

ISTA Procedure 1A


123movies