vi-VNen-US

EMERSON GXT1000-MTPlus230 1000VA / 800W
EMERSON GXT1000-MTPlus230 1000VA / 800W
GXT1000-MTPlus230
6.946.000 VND

The Liebert GXT MT+ features best-in-class power protection for critical applications with the use oftrue on-line double conversion technology. The Liebert GXT MT+ has a comprehensive specification that provides a higher level of availability to the IT equipment. It satisfies safety criteria and electromagnetic compatibility standards while offering intelligent monitoring and network management functions. This high performance UPS with proven reliability is available in a compact tower design.

Features                              

  • Double conversion on-line technology
  • Compact tower design
  • Standard models and long backup models available
  • Extended runtime capabilities by building up additional battery resources
  • Flexible (site specific) battery configuration
  •  Standard model comes with internal battery
  •  Generator-compatible with wide input frequency range (40 to 70 Hz)
  •  0.8 output power factor
  •  Class A electromagnetic interference (EMC)
  • Ultra wide input voltage range
  • High input power factor & low THDi
  • Emergency power off (EPO)
  • Configurable to energy saving mode (ECO)
  • LCD display for operational convenience and status / fault information
  • Multiple AC output interfaces via IEC standard sockets with Programmable output Remote Monitoring is available through USB / RS232, and optional via dry contacts and SNMP

Model

GXT1000-MTPlus230

Capacity (VA/W)

1000 / 800

Input Parameters

Frequency Range

40Hz ~ 70 Hz

Phase

Single phase with ground

Power Factor

≥ 0.99 @ 220 to 230 VAC (input voltage)

Voltage Range

Low Line Transfer

160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 %
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

Low Line Comeback

175 VAC ± 5 %

High Line Transfer

300 VAC ± 5 %

High Line Comeback

290 VAC ± 5 %

Output Parameters

Output Voltage

208/220/230/240VAC

AC Voltage Regulation

± 3% (Batt. Mode)

Frequency Range

47 to 53 Hz or 57 to 63 Hz (Synchronized Range)

Frequency Range (Batt. Mode)

50 Hz ± 0.25Hz

Overload

100% to 110%: audible warning
110% to 130%: UPS shuts down in 30 seconds at battery mode or transfers to bypass mode when the utility is normal.
>130%: UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal.

Current Crest Ratio

3:1

Harmonic Distortion

≤ 3 % THD (Linear Load)
≤ 4 % THD (Linear Load)

Waveform (Batt. Mode)

PureSinewave

Efficiency

AC Mode

~ 85%

Battery Mode

~ 83%

Transfer Time

AC Mode toBatt. Mode

Zero

Inverter to Bypass

4 ms (Typical)

Battery Charger (Standard Model)

Battery Type

12 V / 7 AH

Numbers

3

Typical Recharge Time

4 hours recover to 90% capacity (Typical)

Charging Current

1.0A(max.)

Charging Voltage

41.0 VDC ± 1%

Battery Charger (Long back-up Model)

Numbers

3

Charging Current

4.0 A or 8.0A(max.)

Charging Voltage

41.0 VDC ± 1%

Physical Parameters

Dimension, D X W X H

220 x 145 x 397

Net Weight (kgs)

1000VA-13

800W-7

EmvironmentalParameters

Operation Humidity

20 to 90 % RH @ 0 to 40°C (non-condensing)

Noise Level

Less than 55dBA @ 1 Meter

Management

Smart RS-232 or USB

Supports Windows 98/2000/2003/XP/Vista/2008/ 7, Linux, and MAC

Optional SNMP

Power management from SNMP manager and web browser